Details.
Includes checking refrigerant levels and motor amp draws, checking and rinsing washable filters, analyzing motor operating temperature, checking temperature splits, inspecting the evaporator coil, cleaning the condenser coil, checking the air filter, inspecting the condensate drain, checking input voltage and current, evaluating compressor load amperage, analyzing refrigeration pressures and temperatures, and checking indoor air quality products. The service is intended to maintain peak efficiency and reduce breakdowns.